FEATURES | BENEFITS

  • Low investment and operating costs
  • ± 0.5% accuracy of reading
  • Wide turndown ratio of 60:1
  • Non-intrusive, with no moving parts to wear out, virtually maintenance free and tolerates high flows without damage
  • The slightly modified bore permits unobstructed flow, and minimizes flow disturbances and straight pipe requirements
  • 7 lines sizes (1/2" to 4"): 1/2", 3/4", 1-1/2", 2", 3" & 4"
  • Housing ported with "Thermal Well Supports" for sensors (Energy Management)
  • Compatible with FLOMEC® 09 Electronics Display or FLOMEC QSI I/O Board
  • Fitting Type:NPT, BSP, ANSI Flanged, DIN Flanged
    1/2” to 2” - NPT (Male), BSP (Male) (Rc Thread)
    3” & 4” ANSI Flanged - Polymer or Steel Flange
    3” & 4” DIN Flanged - Steel Flange
    Housing Material:Noryl®
    Pipe Sizes:1/2”, 3/4”, 1”, 1-1/2”, 2”, 3”, 4”
    Flow:Velocity0.25 to 15 FPS
    1/2” (05)0.15 - 10 GPM0.56 - 38 LPM
    3/4” (07)0.3 - 20 GPM1.13 - 76 LPM
    1” (10)0.6 - 40 GPM2.27 - 151 LPM
    1-1/2” (15)1.2 - 80 GPM4.54 - 303 LPM
    2” (20)2.25 - 150 GPM8.5 - 568 LPM
    3” (30)4.5 - 300 GPM17 - 1136 LPM
    4” (40)9 - 600 GPM34 - 2271 LPM
    *Accuracy (% of Reading):Size±2%±0.5%
    1/2” (05)0.15 - 0.6 GPM /
    0.56 - 2.27 LPM
    0.61 - 10 GPM
    2.28 - 38 LPM
    3/4” (07)0.3 - 1.2 GPM /
    0.56 - 4.54 LPM
    1.21 - 20 GPM /
    4.55 - 76 LPM
    1” (10)0.6 - 2.4 GPM /
    2.27 - 9.08 LPM
    2.41 - 40 GPM
    9.09 - 151 LPM
    1-1/2” (15)1.2 - 4.8 GPM /
    4.54 - 18.17 LPM
    4.81 - 80 GPM
    18.18 - 303 LPM
    2” (20)2.25 - 9.0 GPM /
    8.5 - 34.07 LPM
    9.01 - 150 GPM /
    34.08 - 568 LPM
    3” (30)4.5 - 18.0 GPM /
    17 - 68.14 LPM
    18.01 - 300 GPM
    68.15 - 1136 LPM
    4” (40)9 - 36.0 GPM
    34 - 136.28 LPM
    36.01 - 600 GPM /
    136.29 - 2271 LPM
    Operating Temperature Range:1/2" - 2"32o F to 210o F (0o C to 99oC)
    3" & 4"32o F to 180o F (0o C to 82oC)
    Ambient Temperature Range:All Sizes0o F to 140o F (-18o C to 60oC)
    Typical
    K-Factor:
    1/2” (05)4347 PPG1158.5 PPL
    3/4” (07)1937 PPG511.8 PPL
    1” (10)1089 PPG287.7 PPL
    1-1/2” (15)484.1 PPG127.9 PPL
    2” (20)400 PPG105.7 PPL
    3” (30)121 PPG32.0 PPL
    4” (40)68.1 PPG18.0 PPL
    Power Supply:
    Externally Powered
    Voltage Supply (Min): 12VDC or VAC
    Voltage Supply (Max): 36VDC or VAC
    Consumption:Max current consumption (QSE with QSB): 75mA
    Max current consumption (QSE with QSI): 150mA
    Wetted
    Materials:
    BodyNoryl®
    Electrodes316L SS
    SealsNBR O-Rings
    Frequency Range:
    All Sizes
    10 Hz Minimum - 1,000 Hz Maximum (with 09 Display)
    10 Hz Minimum - 3,000 Hz Maximum
    (with Blind Pulse Out)
    Calibration Report:Standard
    N.I.S.T. Available
  • PRODUCT IDENTIFIER
    QSE = Electro-Magnetic Flow Meter
    SIZE
    05 = 1/2 INCH
    07 = 3/4 INCH
    10 = 1 INCH
    15 = 1-1/2 INCH
    20 = 2 INCH
    30 = 3 INCH (Flange only)
    40 = 4 INCH (Flange only)
    FITTING TYPE
    N = NPT (Male)
    B = BSP (Male) (Rc Thread)
    FAP = ANSI Flange - Polymer (3” & 4” Only)
    FAS = ANSI Flange - Steel (3” & 4” Only)
    FDS = DIN Flange - Steel (3” & 4” Only)
    ELECTRONIC CHOICE
    09 = Computer w/Integral Display & Meter Mounted Transmitter
    (Pulse Out) 2-Button Computer, Field-configurable (2 Totals, 2 Cals,
    Rate), Coverplate Transmitter w/Pulse Out (Open Collector Square Wave)
    QB = Meter Mounted Transmitter (Pulse Out)
    Coverplate Transmitter, w/Pulse Out (Open Collector Square Wave)
    COMMUNICATION CHOICE
    Q1 = Integrates with Any Electronic Choice QSI Module:
    Blue Tooth®, Coil/Digital Pulse Input, Pulse Output (Flow or Energy &
    Scalable), RS485 (MODbus RDU), Temperature Inputs, BTU Calculator. Energy Use Computation Note: Energy Use Computation Requires Temperature Sensor Probes (Select Probes Below)
    Q2 = Integrates with Any Electronic Choice QSI Module:
    Blue Tooth®, Coil/Digital Pulse Input, Pulse Output (Flow or Energy &
    Scalable), Data Logger, Temperature Inputs, BTU Calculator.
    Energy Use Computation Note: Energy Use Computation Requires
    Temperature Sensor Probes (Select Probes Below)
    Q3 = Integrates with Any Electronic Choice QSI Module:
    Blue Tooth®, Coil/Digital Pulse Input, Pulse Output (Scalable),
    Data Logger, 4-20mA.
    XX = No Communication Suite
    TEMPERATURE SENSOR PROBES
    1 = Integrates with QSI Communications Choice for Energy Use
    Computation (2ea) 1" Long Temperature Sensor Probes w/Cables
    (10 ft.) (Customer Installed), Used with 1/2" through 2" Meters
    2 = Integrates with QSI Communications Choice for Energy Use
    Computation (2ea) 2" Long Temperature Sensor Probes w/Cables
    (10 ft.) (Customer Installed), Used with 3" and 4" Meters
    X = No Temperature Probes
    PACKAGING
    A = 1/2" - 2" Meters
    B = 3" Meter
    C = 4" Meter
    --->>>> QSE + 30 + FAP + 09 + Q1 + 2 + B = QSE30FAP09Q12B = PART ORDER #
  • Dimensions shown in inches (mm)


    QSE METER DIMENSIONS (NPT, BSP, ANSI FLANGE) listed in inches; millimeters listed in [ ] brackets   
    METER SIZE & FITTINGABCDE
    1/2 in. NPT & BSP5.20 [132.1]5.83 [148.1]10.50 [266.7]5.13 [130.9]1.83 [46.5]
    3/4 in. NPT & BSP5.20 [132.1]5.83 [148.1]10.75 [273.1]5.13 [130.9]1.83 [46.5]
    1 in. NPT & BSP5.20 [132.1]5.83 [148.1]11.00 [279.4]5.13 [130.9]1.83 [46.5]
    1-1/2 in. NPT & BSP5.22 [132.6]6.95 [176.5]11.00 [279.4]6.25 [158.8]2.37 [60.2]
    2 in. NPT & BSP5.22 [132.6]6.95 [176.5]11.00 [279.4]6.25 [158.8]2.37 [60.2]
    3 in. ANSI Flange7.50 [190.5]9.62 [244.3]12.00 [304.8]8.92 [226.6]3.25 [82.6]
    4 in. ANSI Flange9.00 [228.6]10.37 [263.4]12.00 [304.8]9.67 [245.6]4.50 [114.3]

APPLICATIONS

Turf / Irrigation
  • Agriculture Irrigation
  • Turf Irrigation Systems
  • Micro Irrigation Systems
  • HVAC
  • EMS (Energy Management Systems)
  • BAS (Building Automation Systems)
Institutional
  • Chilled water
  • Domestic water (hot and cold)
  • Energy sub-metering (BTU hot and cold)
  • Process (blow down, make up, boiler feed, etc.)

APPROVALS