QSE ELECTROMAGNETIC METER

Slide background
Slide background
Slide background
Slide background

INTRODUCING THE ALL-NEW FLOMEC® QSE ELECTROMAGNETIC METER - A dependable highly accurate electromagnetic flowmeter designed for flow and usage monitoring in a wide variety of applications including: HVAC, Turf/ Irrigation and other water reclamation applications.

Go To Top

FEATURES | BENEFITS

  • Low investment and operating costs
  • ± 0.5% accuracy of reading
  • Wide turndown ratio: 0.25 to 15.0 fps
  • Non-intrusive, with no moving parts to wear out, virtually maintenance free and tolerates high flows without damage
  • The slightly modified bore permits unobstructed flow, and minimizes flow disturbances and straight pipe requirements
  • 7 lines sizes (1/2" to 4"): 1/2", 3/4", 1-1/2", 2", 3" & 4"
  • Housing ported with "Thermal Well Supports" for sensors (Energy Management)
  • Compatible with FLOMEC® 09 Electronics Display or FLOMEC QSI I/O Board
Go To Top

APPLICATIONS

Turf / Irrigation
  • Agriculture Irrigation
  • Turf Irrigation Systems
  • Micro Irrigation Systems
  • HVAC
  • EMS (Energy Management Systems)
  • BAS (Building Automation Systems)
Institutional
  • Chilled water
  • Domestic water (hot and cold)
  • Energy sub-metering (BTU hot and cold)
  • Process (blow down, make up, boiler feed, etc.)
Go To Top

APPROVALS

Go To Top
  • Fitting Type:NPT, BSP, ANSI Flanged, DIN Flanged
    1/2” to 2” - NPT (Male), BSP (Male) (Rc Thread)
    3” & 4” ANSI Flanged - Polymer or Steel Flange
    3” & 4” DIN Flanged - Steel Flange
    Housing Material:Noryl®
    Pipe Sizes:1/2”, 3/4”, 1”, 1-1/2”, 2”, 3”, 4”
    Flow:Velocity0.25 to 15 FPS
    1/2” (05)0.15 - 10 GPM0.56 - 38 LPM
    3/4” (07)0.3 - 20 GPM1.13 - 76 LPM
    1” (10)0.6 - 40 GPM2.27 - 151 LPM
    1-1/2” (15)1.2 - 80 GPM4.54 - 303 LPM
    2” (20)2.25 - 150 GPM8.5 - 568 LPM
    3” (30)4.5 - 300 GPM17 - 1136 LPM
    4” (40)9 - 600 GPM34 - 2271 LPM
    *Accuracy (% of Reading):Size±2%±0.5%
    1/2” (05)0.15 - 0.6 GPM /
    0.56 - 2.27 LPM
    0.61 - 10 GPM
    2.28 - 38 LPM
    3/4” (07)0.3 - 1.2 GPM /
    0.56 - 4.54 LPM
    1.21 - 20 GPM /
    4.55 - 76 LPM
    1” (10)0.6 - 2.4 GPM /
    2.27 - 9.08 LPM
    2.41 - 40 GPM
    9.09 - 151 LPM
    1-1/2” (15)1.2 - 4.8 GPM /
    4.54 - 18.17 LPM
    4.81 - 80 GPM
    18.18 - 303 LPM
    2” (20)2.25 - 9.0 GPM /
    8.5 - 34.07 LPM
    9.01 - 150 GPM /
    34.08 - 568 LPM
    3” (30)4.5 - 18.0 GPM /
    17 - 68.14 LPM
    18.01 - 300 GPM
    68.15 - 1136 LPM
    4” (40)9 - 36.0 GPM
    34 - 136.28 LPM
    36.01 - 600 GPM /
    136.29 - 2271 LPM
    Operating Temperature Range:1/2" - 2"32o F to 210o F (0o C to 99oC)
    3" & 4"32o F to 180o F (0o C to 82oC)
    Ambient Temperature Range:All Sizes0o F to 140o F (-18o C to 60oC)
    Typical
    K-Factor:
    1/2” (05)4347 PPG1158.5 PPL
    3/4” (07)1937 PPG511.8 PPL
    1” (10)1089 PPG287.7 PPL
    1-1/2” (15)484.1 PPG127.9 PPL
    2” (20)400 PPG105.7 PPL
    3” (30)121 PPG32.0 PPL
    4” (40)68.1 PPG18.0 PPL
    Power Supply:
    Externally Powered
    Voltage Supply (Min): 12VDC or VAC
    Voltage Supply (Max): 36VDC or VAC
    Consumption:Max current consumption (QSE with QSB): 75mA
    Max current consumption (QSE with QSI): 150mA
    Wetted
    Materials:
    BodyNoryl®
    Electrodes316L SS
    SealsNBR O-Rings
    Frequency Range:
    All Sizes
    10 Hz Minimum - 1,000 Hz Maximum (with 09 Display)
    10 Hz Minimum - 3,000 Hz Maximum
    (with Blind Pulse Out)
    Calibration Report:Standard
    N.I.S.T. Available
  • PRODUCT IDENTIFIER
    QSE = Electro-Magnetic Flow Meter
    SIZE
    05 = 1/2 INCH
    07 = 3/4 INCH
    10 = 1 INCH
    15 = 1-1/2 INCH
    20 = 2 INCH
    30 = 3 INCH (Flange only)
    40 = 4 INCH (Flange only)
    FITTING TYPE
    N = NPT (Male)
    B = BSP (Male) (Rc Thread)
    FAP = ANSI Flange - Polymer (3” & 4” Only)
    FAS = ANSI Flange - Steel (3” & 4” Only)
    FDS = DIN Flange - Steel (3” & 4” Only)
    ELECTRONIC CHOICE
    09 = Computer w/Integral Display & Meter Mounted Transmitter
    (Pulse Out) 2-Button Computer, Field-configurable (2 Totals, 2 Cals,
    Rate), Coverplate Transmitter w/Pulse Out (Open Collector Square Wave)
    QB = Meter Mounted Transmitter (Pulse Out)
    Coverplate Transmitter, w/Pulse Out (Open Collector Square Wave)
    COMMUNICATION CHOICE
    Q1 = Integrates with Any Electronic Choice QSI Module:
    Blue Tooth®, Coil/Digital Pulse Input, Pulse Output (Flow or Energy &
    Scalable), RS485 (MODbus RDU), Temperature Inputs, BTU Calculator. Energy Use Computation Note: Energy Use Computation Requires Temperature Sensor Probes (Select Probes Below)
    Q2 = Integrates with Any Electronic Choice QSI Module:
    Blue Tooth®, Coil/Digital Pulse Input, Pulse Output (Flow or Energy &
    Scalable), Data Logger, Temperature Inputs, BTU Calculator.
    Energy Use Computation Note: Energy Use Computation Requires
    Temperature Sensor Probes (Select Probes Below)
    Q3 = Integrates with Any Electronic Choice QSI Module:
    Blue Tooth®, Coil/Digital Pulse Input, Pulse Output (Scalable),
    Data Logger, 4-20mA.
    XX = No Communication Suite
    TEMPERATURE SENSOR PROBES
    1 = Integrates with QSI Communications Choice for Energy Use
    Computation (2ea) 1" Long Temperature Sensor Probes w/Cables
    (10 ft.) (Customer Installed), Used with 1/2" through 2" Meters
    2 = Integrates with QSI Communications Choice for Energy Use
    Computation (2ea) 2" Long Temperature Sensor Probes w/Cables
    (10 ft.) (Customer Installed), Used with 3" and 4" Meters
    X = No Temperature Probes
    PACKAGING
    A = 1/2" - 2" Meters
    B = 3" Meter
    C = 4" Meter
    --->>>> QSE + 30 + FAP + 09 + Q1 + 2 + B = QSE30FAP09Q12B = PART ORDER #
  • Dimensions shown in inches (mm)


    QSE METER DIMENSIONS (NPT, BSP, ANSI FLANGE) listed in inches; millimeters listed in [ ] brackets   
    METER SIZE & FITTINGABCDE
    1/2 in. NPT & BSP5.20 [132.1]5.83 [148.1]10.50 [266.7]5.13 [130.9]1.83 [46.5]
    3/4 in. NPT & BSP5.20 [132.1]5.83 [148.1]10.75 [273.1]5.13 [130.9]1.83 [46.5]
    1 in. NPT & BSP5.20 [132.1]5.83 [148.1]11.00 [279.4]5.13 [130.9]1.83 [46.5]
    1-1/2 in. NPT & BSP5.22 [132.6]6.95 [176.5]11.00 [279.4]6.25 [158.8]2.37 [60.2]
    2 in. NPT & BSP5.22 [132.6]6.95 [176.5]11.00 [279.4]6.25 [158.8]2.37 [60.2]
    3 in. ANSI Flange7.50 [190.5]9.62 [244.3]12.00 [304.8]8.92 [226.6]3.25 [82.6]
    4 in. ANSI Flange9.00 [228.6]10.37 [263.4]12.00 [304.8]9.67 [245.6]4.50 [114.3]
Go To Top

PRESS KIT

G2 SERIES METERS

Slide background
Slide background
Slide background
Slide background
Slide background

The unique modular approach of the G2 Industrial Turbine Meter line allows the end user to design a meter to match a specific application. When choosing a G2Series Meter, select from a wide variety of materials and sizes. These meters offer high accuracy at a lower cost, are compact and include a self-contained design. G2 Series Meters are field serviceable.

DATA SHEET
Go To Top

METER TYPE | APPLICATIONS | APPROVALS

G2 Stainless Steel Turbine Meter:

G2 Stainless Steel Meters are accurate, rugged and dependable. Made from stainless steel, this meter is compatible with water and most chemicals: Ammonium and Fuel products. Designed for thin fluids < 100 cp.

APPROVALS:

g2-approvals-full

G2 High Pressure Turbine Meter:

Excellent choice for most high pressure applications like spray washers and hydraulic systems. PSIG for the FLOMEC® High Pressure Meter is 3,000 compared to 1,500 for the standard stainless steel meter. This meter has excellent chemical compatibility and designed for thin fluids < 100 cp.

APPROVALS:

g2-approvals-hp

G2 ANSI Flange Turbine Meter:

Provides a stainless steel meter with 150# ANSI Flanges that installs in-line quickly. Combined with a FLOMEC® Display Electronics, this flow meter offers a complete, accurate, metering system.

APPROVALS:

g2-approvals-full

G2 Tri-Clover Turbine Meter:

The FLOMEC® Stainless Steel Meters with Tri-Clover® fittings can be used with food and beverage preprocess applications. These meters come in five sizes to fit most every application.

APPROVALS:

g2-approvals-full

G2 Aluminum Turbine Meter:

Best suited for petroleum based products, this modular design allows for maximum flexibility. Models are available with ISO* or NPT fittings. Designed for thin fluids < 100 cp.

APPROVALS:

g2-approvals-full

G2 Brass Turbine Meter:

The G2 Brass Meter provides another material choice for fluid compatibility. The G2 Brass Meter works with most water based applications, such as glucose and lacquer thinners. Designed for thin fluids < 100 cp.

APPROVALS:

g2-approvals-full

G2 PVDF Turbine Meter:

The G2 PVDF Meter handles aggressive chemicals. The PVDF housing material resists abrasion and has great chemical compatibility with chemicals like: Bleach, Ferric Chloride, Phenol, Sulfuric Acid or Phosphoric Acid. Designed for thin fluids < 100 cp.

APPROVALS:

g2-approvals-full

Go To Top